• 10.24kWH-20.48kWH Stacked Energy Storage System(ESS)
10.24kWH-20.48kWH Stacked Energy Storage System(ESS)
$36840.00
Model
SCESS-5/30K-A
SCESS-5/30K-B
SCESS-5/25K-A
SCESS-5/25K-B
SCESS-5/20K-A
SCESS-5/20K-B
SCESS-5/15K-A
SCESS-5/15K-B
SCESS-5/10K-A
SCESS-5/10K-B
Basic info
Brand RW Energy
Model NO. Stacked ESS
Rated Output Rating 5kW
Energy storage capacity 30.72kWh
Cell quality Class A
Series Residential energy storage
Product Detail

Stacked ESS

 企业微信截图_1728974724403.png

Peculiarity

  • Custom stacking capacity, integrated installation free.

  • Battery pack is replaceable, can be adapted to a variety of batteries, for different batteries to achieve different charging and discharging strategies.

  • Energy scheduling can be regulated, users can change the charge and discharge according to the power consumption policy of different periods in the region; Low logical O&M cost.

  • Support battery pack voltage, capacity customization, to meet different use environment

  • Mature technology, long cycle life, high safety performance.

  • Modular design, high power density, easy maintenance.

Technical parameter

image.png

image.png

Note:

  • The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.

  •  Class A cell warranty 60 months, Class B cell warranty 30 months.

How to ensure that the voltage and capacity of each battery cell are consistent in ESS?

The role of the Battery Management System (BMS).

  • Real-time monitoring:The BMS monitors parameters such as voltage, current, and temperature of each battery cell in real time through sensors to ensure the health status of each cell.

  • Equalization management:The equalization circuit (Balancing Circuit) in the BMS is used to adjust the voltage differences between each battery cell. When a cell voltage is detected to be lower than the set value, the equalization circuit will perform voltage compensation in a passive or active way to make the voltages of all cells tend to be consistent.

Equalization strategies.

  • Passive balancing:Excess charge is dissipated through resistors connected in parallel to the battery cells, thereby making the voltges of each cell tend to be consistent.
    The disadvantage is that it can only work during the battery charging process and has a large energy loss.

  • Active balancing:Using a bidirectional converter or a dedicated equalization chip to transfer charge between battery cells to achieve energy transfer, thereby making the voltages of each cell consistent.
    The advantage is that it can be adjusted bidirectionally. It can equalize during charging and discharging, and has low energy loss.




Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!